誘導モーター負荷における発電機容量の選定計算:ポンプ・コンプレッサー・空調

誘導モーター負荷における発電機容量の選定計算:ポンプ・コンプレッサー・空調

Executive Summary: The #1 Sizing Mistake in Commercial Power

The single most frequent cause of premature generator failure, nuisance tripping, and customer dissatisfaction is undersizing for electric motor startup current. Facilities managers often check the nameplate of a 3 HP drainage pump or a 5 HP air compressor, note that 3 HP equals approximately 2.2 kW, and conclude that a 3 kW generator is sufficient.

In reality, connecting that 3 HP pump to a 3 kW generator will cause the engine to immediately choke, drop engine RPM, and trigger the circuit breaker.

Electric motors do not behave like simple resistive heating elements or incandescent light bulbs. During the first few cycles of startup, an inductive electric motor creates an instantaneous electrical demand known as Locked Rotor Amperage (LRA), requiring 3x to 7x its normal running power.

This 2026 engineering guide provides electrical contractors, industrial equipment distributors, and site engineers with step-by-step mathematical formulas and a practical sizing matrix for matching commercial generators to heavy inductive loads.


1. Resistive vs. Inductive Loads: Understanding Inrush Current

All electrical appliances fall into one of two fundamental categories:

Resistive Loads (Unity Power Factor, PF = 1.0)

  • Examples: Electric heaters, halogen work lights, toasters, curling irons.
  • Characteristics: The electrical current is directly in-phase with voltage. There are no moving mechanical components or magnetic coils.
  • Starting Requirement: Starting watts equal running watts (1:1 ratio). A 2,000W heater requires exactly 2,000W of generator capacity.

Inductive Loads (Lagging Power Factor, PF = 0.8)

  • Examples: Submersible water pumps, reciprocating air compressors, concrete mixers, HVAC chillers, power saws.
  • Characteristics: Utilizes copper electromagnets to create rotating magnetic fields. Current lags behind voltage.
  • Starting Requirement: Requires an initial burst of reactive magnetizing current to establish the magnetic flux and overcome mechanical inertia from a standstill. This inrush current lasts from 50 milliseconds to 3 full seconds.

$$\text{Starting Surge Watts} = \text{Running Watts} \times \text{Starting Multiplier (2.5x to 7x)}$$


2. NEMA Motor Code Letters & Starting Multipliers

The National Electrical Manufacturers Association (NEMA) assigns code letters (from A to V) to motor nameplates, defining the kilovolt-amperes required per horsepower with locked rotor:

Motor Starter TypeStarting MultiplierInrush Current vs. Full Load CurrentApplication Examples
Direct-on-Line (DOL) - Standard3.0x – 6.0x500% – 700% of FLASubmersible pumps, air compressors, table saws
Capacitor-Start Induction Motor4.0x – 7.0x600% – 800% of FLAHeavy refrigeration compressors, pressure washers
Star-Delta Starter (Y-Δ)2.0x – 3.0x200% – 300% of FLALarge workshop machinery, ventilation blowers
Electronic Soft-Starter1.8x – 2.5x200% – 250% of FLACommercial water pumps, industrial conveyors
Variable Frequency Drive (VFD)1.0x – 1.2x100% – 120% of FLAModern elevators, precision industrial pumps

3. Commercial Sizing Matrix: 1 HP to 10 HP Motors

Below is the verified engineering sizing table for commercial electric motors running at standard 230V single-phase or 400V three-phase (0.8 Power Factor, DOL Starter):

Electric Motor RatingRunning Watts (kW)DOL Starting Surge (kW)Minimum Generator Capacity (Direct-on-Line)Minimum Generator Capacity (With Soft Starter / VFD)
0.5 HP (370 W)0.45 kW1.8 kWSUPERKIGER KG2500 (2.0 kW Gasoline)1.0 kW Inverter Generator
1.0 HP (750 W)0.90 kW3.6 kWSUPERKIGER KG5000DE (5.0 kW Silent Diesel)2.0 kW Generator Set
2.0 HP (1.5 kW)1.80 kW7.2 kWSUPERKIGER KG10000DE (8.0 kW Silent Diesel)4.0 kW Generator Set
3.0 HP (2.2 kW)2.60 kW10.5 kWSUPERKIGER KG13000E / KG15000DE (10–12 kW)5.5 kW Generator Set
5.0 HP (3.7 kW)4.40 kW17.5 kWSUPERKIGER 18–20 kW Commercial Diesel8.0 kW Generator Set
7.5 HP (5.5 kW)6.50 kW26.0 kWSUPERKIGER 25–30 kW Industrial Diesel12.0 kW Generator Set
10.0 HP (7.5 kW)9.00 kW36.0 kWSUPERKIGER 40–50 kW Industrial Diesel16.0 kW Generator Set

4. Alternator Subtransient Reactance & AVR Performance

When an electric motor suddenly starts, the generator’s terminal voltage drops instantly. The depth of this voltage dip is governed by the alternator’s Subtransient Reactance (X"d):

  • Cheap Alternators (High X"d > 18%): Experience voltage dips exceeding 30%. Magnetic starter contactors drop out, the motor stalls, and equipment resets.
  • SUPERKIGER Commercial Alternators (Low X"d < 12%): Heavy copper winding geometry with low internal impedance limits instantaneous voltage drop to under 15%, allowing the motor to accelerate smoothly to rated RPM without tripping control circuits.

Furthermore, SUPERKIGER diesel generators feature high-excitation digital AVR systems that supply up to 300% field forcing current for 10 seconds during sudden inductive shock loads.


Factory Verification: Sizing heavy motor loads requires authentic generator reactance. Learn how we verify low subtransient reactance on our testing line: China Generator Factory Sourcing & Load-Bank Testing Guide. For pump sizing, see our Gasoline Water Pumps Sourcing Guide.


For custom motor starting calculations or three-phase commercial power sizing: [email protected] | SUPERKIGER Product Catalog

よくある質問

なぜ2馬力(1.5 kW)の電動水中ポンプを始動するのに5 kW〜6 kWの発電機が必要なのですか?

誘導モーターは始動直後の0.5〜2秒間に定格運転電流(FLA)の3〜7倍もの拘束回転子電流(LRA:始動突入電流)を必要とします。定常運転電力は1.5〜1.8 kWでも、始動時の瞬時電力は5.0〜7.2 kWに達するため、容量の小さい発電機では電圧降下やエンストが発生します。

モーター負荷向けに発電機を選定する際、kWとkVAの違いは何ですか?

kW(キロワット)は実際に仕事をする有効電力であり、kVA(キロボルトアンペア)はコイルの磁界形成に必要な無効電力を含んだ皮相電力です。誘導モーターの力率(cos φ)は通常0.8前後のため、発電機にはkWとkVAの両方を満たす余裕が必要です。

ソフトスターターやインバーター駆動(VFD)を使うと必要な発電機容量を減らせますか?

はい。直入れ始動(DOL)では定格の約600%の突入電流が発生しますが、ソフトスターターは200%〜250%、VFD(可変周波数ドライブ)は100%〜120%に抑制できるため、必要な発電機容量を最大50%小型化できます。

デジタルAVR(自動電圧調整器)はモーター始動時の電圧降下をどのように防ぎますか?

モーター始動時に端子電圧が急落すると、高速デジタルAVRが数ミリ秒以内にオルタネーター界磁巻線への励磁電流を最大化し、電磁接触器(マグネットスイッチ)がトリップする前に電圧を回復させます。

← 一覧に戻る

ビジネス拡大をお考えですか?

お気軽にご連絡ください。電子カタログとサンプルをお送りします。

今すぐ問い合わせる
WhatsApp
メール